Witryna19 wrz 2024 · The following tests were performed: 3-point bending, fracture toughness, and axial compression. Six sets of whole-bone samples of human male cadaveric humerus, ulna, and radius (age of donor: 35 to 56 years) were tested. The results were analyzed for statistical significance by 2-stage, repeated-measure analysis of variance … WitrynaThe aim of the present study was to evaluate the flexural strength and the Weibull modulus of a microhybrid and a nanofill composite by means of 3- and 4-point bending tests. Thirty specimens...
Caractérisation mécanique par flexion, nano- et macro …
The three-point bending technique was used to assess the mechanical properties (fracture point, stiffness, and elasticity) of the tibia. A constant amount of force was applied to the midpoint of the tibia diaphysis to determine the maximum load that could be placed on the tibia until fracture/breakage … Zobacz więcej Six-week-old C57BL/6 female mice were acquired from Envigo (Indianapolis, IN, USA) and housed in the animal facility at the University of Central Arkansas (Conway, AR, … Zobacz więcej All data are expressed as the mean ± S.E. for the number of mice used (Table 1). A log transformation was used on nonparametric data. Data were analyzed using a two-way analysis of variance to detect the effect … Zobacz więcej The modified, three-point bending apparatus used in this study has recently been described [16]. Before experimentation, … Zobacz więcej The tibial length was measured using a digimatic digital caliper (Mitutoyo, IL, USA). The midpoint of the tibia was sectioned using an IsoMet1000 Precision Saw (Buehler, IL, USA) equipped with an IsoMet 15HC … Zobacz więcej WitrynaComparisons of nanoindentation, 3-point bending, and tension tests for orthodontic wires The 3 testing methods did not yield identical values of hardness and elastic … hazet 199-4 refillable spray bottle
Experimental assessment of biomechanical properties in …
WitrynaA three-point bending apparatus was designed to characterize the mechanical properties of miniature beams of cortical bone, approximately 5 mm in length. The … Witryna[Reference Donohue, Ambrus and Kalidindi 13, Reference Rittel and Ravichandran 22] The Young's moduli of polymers used in the simulation were obtained from the independent three-point bending experiments, rather than the Young's moduli measured from the indentation experiments. Under the maximum indentation force 10 mN, the … WitrynaA three-point bending apparatus was designed to characterize the mechanical properties of miniature beams of cortical bone, approximately 5 mm in length. The potential sources of error were... hazet 1991-1 infrarot-thermometer